SCB10 1000kva 10kv 3 Phase Cast Resin Cooling Fan Dry Power Transformer
Low Loss And Low Noise Low loss, low partial discharge, low noise, strong heat dissipation, and can be operated at 120% rated load under forced air cooling. |
Good Moisture Resistance It has good moisture-proof performance and can operate normally under 100% humidity. It can be put into operation without pre-drying after shutdown. |
Operation Safety It is safe to operate, fire-resistant, non-polluting, and can be installed directly in the load center. |
Temperature Protection Control Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of the transformer. |
Low Operation Cost Maintenance-free, simple installation and low overall operating cost. |
High Reliability According to the operation research of the products that have been put into operation, the reliability of the products has reached the international advanced level. |
Rated Capacity |
1000kVA |
High Voltage |
10kV |
Low Voltage |
0.4kV |
Impedance Voltage |
6% |
No-load Loss |
1.77kW |
Load Loss |
8.13kW |
No-load Current |
0.4% |
Connection Method |
Dyn11 |
Insulating Level |
F/F |
Noise |
43dB |
Size |
1500x1270x1385mm |
Weight |
3395kg |
technical parameter
1. Use frequency: 50/60HZ;
2. No-load current:<4%;
3. Compression strength: 20000V/min without breakdown; Test instrument: YZ1802 withstand voltage tester (20mA);
4. Insulation grade: F (special grade can be customized);
5. Insulation resistance: ≥ 2M Ω test instrument: ZC25B-4 megohmmeter<1000 V);
6. Connection mode: Y/Y, △/Y0, Yo/△, auto coupling (optional);
7. Allowable temperature rise of coil: I00K;
8. Heat dissipation mode: natural air cooling or temperature controlled automatic heat dissipation;
Noise coefficient: ≤ 30dB.
Cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). In case of natural air cooling, the transformer can operate continuously for a long time under rated capacity. In case of forced air cooling, the output capacity of transformer can be increased by 50%. It is applicable to intermittent overload operation or emergency overload operation; Due to the large increase of load loss and impedance voltage during overload, it is in a non economic operation state, so it should not be in a long-term continuous overload operation
Low Loss And Low Noise Low loss, low partial discharge, low noise, strong heat dissipation, and can be operated at 120% rated load under forced air cooling. |
Good Moisture Resistance It has good moisture-proof performance and can operate normally under 100% humidity. It can be put into operation without pre-drying after shutdown. |
Operation Safety It is safe to operate, fire-resistant, non-polluting, and can be installed directly in the load center. |
Temperature Protection Control Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of the transformer. |
Low Operation Cost Maintenance-free, simple installation and low overall operating cost. |
High Reliability According to the operation research of the products that have been put into operation, the reliability of the products has reached the international advanced level. |
Rated Capacity |
1000kVA |
High Voltage |
10kV |
Low Voltage |
0.4kV |
Impedance Voltage |
6% |
No-load Loss |
1.77kW |
Load Loss |
8.13kW |
No-load Current |
0.4% |
Connection Method |
Dyn11 |
Insulating Level |
F/F |
Noise |
43dB |
Size |
1500x1270x1385mm |
Weight |
3395kg |
technical parameter
1. Use frequency: 50/60HZ;
2. No-load current:<4%;
3. Compression strength: 20000V/min without breakdown; Test instrument: YZ1802 withstand voltage tester (20mA);
4. Insulation grade: F (special grade can be customized);
5. Insulation resistance: ≥ 2M Ω test instrument: ZC25B-4 megohmmeter<1000 V);
6. Connection mode: Y/Y, △/Y0, Yo/△, auto coupling (optional);
7. Allowable temperature rise of coil: I00K;
8. Heat dissipation mode: natural air cooling or temperature controlled automatic heat dissipation;
Noise coefficient: ≤ 30dB.
2. No-load current:<4%;
3. Compression strength: 20000V/min without breakdown; Test instrument: YZ1802 withstand voltage tester (20mA);
4. Insulation grade: F (special grade can be customized);
5. Insulation resistance: ≥ 2M Ω test instrument: ZC25B-4 megohmmeter<1000 V);
6. Connection mode: Y/Y, △/Y0, Yo/△, auto coupling (optional);