Two fault types for quality transformer 800kva
- Categories:Industry Dynamics
- Author:
- Origin:
- Time of issue:2022-06-16
- Views:0
(Summary description)(1) circuit failure
For the circuit fault of quality transformer 800kva, it mainly refers to the short circuit at the outlet of quality transformer 800kva, and the short circuit to ground between the leads or windings inside the quality transformer 800kva, and the short circuit between phases and phases.
Two fault types for quality transformer 800kva
(Summary description)(1) circuit failure
For the circuit fault of quality transformer 800kva, it mainly refers to the short circuit at the outlet of quality transformer 800kva, and the short circuit to ground between the leads or windings inside the quality transformer 800kva, and the short circuit between phases and phases.
- Categories:Industry Dynamics
- Author:
- Origin:
- Time of issue:2022-06-16
- Views:0
(1) circuit failure
For the circuit fault of quality transformer 800kva, it mainly refers to the short circuit at the outlet of quality transformer 800kva, and the short circuit to ground between the leads or windings inside the quality transformer 800kva, and the short circuit between phases and phases. In fact, this kind of fault is a very common problem among the many fault problems of quality transformer 800kva, and there are many actual cases of this fault. For the problem of short circuit at the low-voltage outlet of quality transformer 800kva, in order to solve the problem, the windings are generally replaced at the fault. When the fault is serious, it may be necessary to replace all the windings, so as to reduce the probability of failure as much as possible and greatly reduce the It is necessary to pay great attention to the serious economic and personal and property losses caused by power failures.
(2) Fault problem of winding
The winding faults can be divided into the following types in detail: the welding joints of the joints are extremely prone to cracking problems, phase-to-phase short-circuit problems, short-circuits in the turn direction, and grounding faults of the windings. The reasons for the above faults can be summarized as follows: there is a problem with the insulation problem of quality transformer 800kva; there are sundries in the winding, aging insulators; the work force of quality transformer 800kva is insufficient; there is a problem with the winding due to deformation: the winding is affected by water vapor; the transformer 800kva high temperature.