(Summary description)Under the specified operating environment and operating conditions of 2500 kva transformers from China manufacturer, the main technical data are generally marked on the nameplate of the transformer. Mainly include: rated capacity, rated voltage and its tap, rated frequency, winding connection group and rated performance data (impedance voltage, no-load current, no-load loss and load loss) and total weight.
Parameters of 2500 kva transformer from China manufacturer
(Summary description)Under the specified operating environment and operating conditions of 2500 kva transformers from China manufacturer, the main technical data are generally marked on the nameplate of the transformer. Mainly include: rated capacity, rated voltage and its tap, rated frequency, winding connection group and rated performance data (impedance voltage, no-load current, no-load loss and load loss) and total weight.
- Categories:Industry Dynamics
- Author:
- Origin:
- Time of issue:2022-10-27
- Views:0
Under the specified operating environment and operating conditions of 2500 kva transformers from China manufacturer, the main technical data are generally marked on the nameplate of the transformer. Mainly include: rated capacity, rated voltage and its tap, rated frequency, winding connection group and rated performance data (impedance voltage, no-load current, no-load loss and load loss) and total weight.
A. Rated capacity (kVA): rated voltage. The capacity that can be delivered during continuous operation at rated current.
B. Rated voltage (KV): the working voltage that the 2500 kva transformer from China manufacturer can withstand when it runs for a long time. In order to meet the needs of grid voltage changes, the high-voltage side of the transformer has taps, and the output voltage of the low-voltage side is adjusted by adjusting the number of turns of the high-voltage winding.
C. Rated current (A): The 2500 kva transformer from China manufacturer is allowed to pass the current for a long time under the rated capacity.
D. No-load loss (kW): When the rated voltage of the rated frequency is applied to the terminals of one winding, the active power absorbed when the remaining windings are open-circuited. It is related to the performance and manufacturing process of the iron core silicon steel sheet, and the applied voltage.
E. No-load current (%): When the 2500 kva transformer from China manufacturer is under no-load on the secondary side of the rated voltage, the current passing through the primary winding. Generally expressed as a percentage of rated current. F. Load loss (kW): short-circuit the secondary winding of the transformer, and pass the rated current into the rated tap position of the primary winding, the power consumed by the transformer at this time.