Power Transformer Price 1000kva Three Phase 1600 Kva Dry Type Transformer(prefabricated substation)
PRODUCT DESCRIPTION
A. It is safe to operate, fire-resistant, non-polluting, and can be installed directly in the load center.
B. Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of the transformer.
Characteristics of the site
Dry-type transformers are widely used in local lighting, high-rise buildings, airports, wharves, CNC machinery and other places. Simply speaking, dry-type transformers refer to transformers whose core and windings are not immersed in insulating oil.
work environment
1.0 - 40 (℃), relative humidity<70%;
2. Altitude: not more than 2500 meters;
3. Avoid rain, moisture, high temperature, high heat or direct sunlight. The distance between its cooling vent and surrounding objects shall be no less than 40cm;
4. Prevent working in places with corrosive liquid, gas, dust, conductive fiber or metal fines;
5. Prevent working in places with vibration or electromagnetic interference;
6. Avoid long-term inverted storage and transportation, and avoid strong impact.
technical parameter
1. Use frequency: 50/60HZ;
2. No-load current:<4%;
3. Compression strength: 20000V/min without breakdown; Test instrument: YZ1802 withstand voltage tester (20mA);
4. Insulation grade: F (special grade can be customized);
5. Insulation resistance: ≥ 2M Ω test instrument: ZC25B-4 megohmmeter<1000 V);
6. Connection mode: Y/Y, △/Y0, Yo/△, auto coupling (optional);
7. Allowable temperature rise of coil: I00K;
8. Heat dissipation mode: natural air cooling or temperature controlled automatic heat dissipation;
Noise coefficient: ≤ 30dB.
Features:
The cooling mode is divided into natural air cooling (AN) and forced air cooling (AF). During natural air cooling, the transformer can operate continuously for a long time under rated capacity. When forced air cooling is applied, the output capacity of transformer can be increased by 50%. It is applicable to intermittent overload operation or emergency overload operation; Due to the large increase of load loss and impedance voltage during overload, it is in non-economic operation state, so it should not be kept in long-term continuous overload operation。
PRODUCT DESCRIPTION
A. It is safe to operate, fire-resistant, non-polluting, and can be installed directly in the load center.
B. Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of the transformer.
Characteristics of the site
Dry-type transformers are widely used in local lighting, high-rise buildings, airports, wharves, CNC machinery and other places. Simply speaking, dry-type transformers refer to transformers whose core and windings are not immersed in insulating oil.
work environment
1.0 - 40 (℃), relative humidity<70%;
2. Altitude: not more than 2500 meters;
3. Avoid rain, moisture, high temperature, high heat or direct sunlight. The distance between its cooling vent and surrounding objects shall be no less than 40cm;
4. Prevent working in places with corrosive liquid, gas, dust, conductive fiber or metal fines;
5. Prevent working in places with vibration or electromagnetic interference;
6. Avoid long-term inverted storage and transportation, and avoid strong impact.
technical parameter
1. Use frequency: 50/60HZ;
2. No-load current:<4%;
3. Compression strength: 20000V/min without breakdown; Test instrument: YZ1802 withstand voltage tester (20mA);
4. Insulation grade: F (special grade can be customized);
5. Insulation resistance: ≥ 2M Ω test instrument: ZC25B-4 megohmmeter<1000 V);
6. Connection mode: Y/Y, △/Y0, Yo/△, auto coupling (optional);
7. Allowable temperature rise of coil: I00K;
8. Heat dissipation mode: natural air cooling or temperature controlled automatic heat dissipation;
Noise coefficient: ≤ 30dB.
Features:
The cooling mode is divided into natural air cooling (AN) and forced air cooling (AF). During natural air cooling, the transformer can operate continuously for a long time under rated capacity. When forced air cooling is applied, the output capacity of transformer can be increased by 50%. It is applicable to intermittent overload operation or emergency overload operation; Due to the large increase of load loss and impedance voltage during overload, it is in non-economic operation state, so it should not be kept in long-term continuous overload operation。


2. No-load current:<4%;
3. Compression strength: 20000V/min without breakdown; Test instrument: YZ1802 withstand voltage tester (20mA);
4. Insulation grade: F (special grade can be customized);
5. Insulation resistance: ≥ 2M Ω test instrument: ZC25B-4 megohmmeter<1000 V);
6. Connection mode: Y/Y, △/Y0, Yo/△, auto coupling (optional);




Product consultation

Add: No. 2, Shashui Village, Laobian, Danzao Town, Nanhai District, Foshan City, Guangdong Province, China
Tel:+86-13431672143/86-13229275711/+86-18603093593
Fax:+86-757-8109-2137
WhatsApp:+86-13695195603/86-13229275711/+86-18603093593
Email:zjx@shengtetransformer.com
Email:owen@shengtetransformer.com
Email:juanie@shengtetransformer.com
Code:528000
Website:www.senttransformer.com